BEAMEX MC5 MANUAL PDF

User Guide Applies for Main Firmware version 1. Should any errors be detected, we would greatly appreciate to receive suggestions to improve the quality of the contents of this manual. The above not withstanding, we can assume no responsibility for any errors in this manual or their eventual consequences. We reserve rights to make modifications to this manual without any further notice. For more detailed technical data about the MC5 Multifunction Calibrator, please contact the manufacturer. Any use of the word HART hereafter in this document implies the registered trademark.

Author:Voshura Goltimi
Country:Honduras
Language:English (Spanish)
Genre:Health and Food
Published (Last):12 June 2008
Pages:341
PDF File Size:12.94 Mb
ePub File Size:10.51 Mb
ISBN:738-4-72772-930-7
Downloads:82568
Price:Free* [*Free Regsitration Required]
Uploader:Shaktisho



User Guide Applies for Main Firmware version 1. Should any errors be detected, we would greatly appreciate to receive suggestions to improve the quality of the contents of this manual. The above not withstanding, we can assume no responsibility for any errors in this manual or their eventual consequences.

We reserve rights to make modifications to this manual without any further notice. Any use of the word HART hereafter in this document implies the registered trademark. Other trademarks are property of their respective owners. About This Manual Operational Sections and Connections Ex Information and Approvals General Description Firmware Update Startup Procedure Pressure Measurement Opening the Step or Ramp Configuration Window Mathematical Special Measurements..

Display Mode Settings Things to Consider when Measuring Pressure Phases of Instrument Calibration Selecting the Instrument to Be Calibrated Adding New Instruments Calibration Result Windows Feedback We want to improve our products and services constantly. Therefore wed like to know Your opinion of the product You use. Please spend a moment of Your valuable time in filling this form. All respondents will receive a surprise gift in return.

Certain questions can be answered immediately after receiving the product. Others require some use of the product before You are able to answer them. The best way to fill the form is to answer the items as it applies, and send the form to us when all items are answered.

There are however no definite restricitions; fill in the form when you feel like it all items need not be answered. Then send it to Beamex using one of the possibilities listed below. Any comments when receiving the product. Did the package contain all required items and was it as expected? For how long have you been using the product? How helpful was the manual in using the product? How well did the product suit your needs? How satisfied are you with the product? Did anything in the product exceed your expectations?

In that case, what was it? Did anything in the product disappoint you? In that case, please specify. Please contact me concerning the Feedback I have given. I want to receive more information on Beamex products. A general description of MC5-IS hardware. A general description of MC5-IS firmware.

The modularity and options of MC5-IS. Safety precautions and warnings. Briefly about how to service MC5-IS. Introduction Congratulations for selecting the ultimate calibration tool! MC5-IS modularity allows customized construction. If requirements increase in the future, new functionality may be added by getting additional modules, e.

Thanks to the logical user interface MC5-IS is very easy to use. The large graphical display guides the user in different languages and it displays results both numerically and graphically. MC5-IS performs automatic calibration of electrical and temperature process instruments.

MC5-IS represents the state of the art in accuracy, adaptability and all-round usability. Part A discusses general matters. There is also a chapter about safety. Part D concentrates on calibration and matters related to calibration like handling instrument data. The even page header displays the title of the active part.

The odd page header displays the main subject Heading level 1. The header of each odd page also indicates the active part as shown in the adjacent picture with Part B active. Use the information provided in the headers as a quick guide when searching for a particular subject.

Typographical Conventions All examples of user interface texts are printed using 8 pt Arial Black, e. It should be free of scrapes and scratches and in proper operation order upon receipt. The receiver should, however, inspect the unit for any damage that may have occurred during transit.

If there are signs of obvious mechanical damage, package contents are incomplete, or the instrument does not operate according to specifications, contact the purchasing sales office as soon as possible. If you have to return the instrument to the factory for any reason, use the original packing whenever possible.

Include a detailed description of the reason for the return. Warning: The accessory polyurethane hose supplied with the calibrator is rated to the maximum pressure of 20 bar at 21C psi at 70F. Applying higher pressure can be hazardous. Note: The stickers and the batteries may be affected when storing longer periods in extreme conditions. All sections and connections are presented in detail on the next pages. Keep in mind that the previous picture as well as all pictures of MC5-IS in this manual has an example configuration of modules.

The configuration of your MC5-IS may vary significantly from the one in the picture. The connector is located on the right hand side of the upper panel and is marked with PX1 in a sticker on the upper panel. One of them may be an internal barometric module. The connectors for Internal Pressure modules start from the second connector on the left. The possible Barometric Module is always located as second from right and it measures the barometric pressure through a connection in the back panel of MC5-IS.

Normally nothing need to connected to the barometric pressure modules connector. Internal pressure modules are marked with P1 P3. The recommended pressure medium for all internal pressure modules is clean air.

To avoid damaging the calibrator, use hand tightening only when connecting the pressure measurement hoses max. If the use of tools is required to secure the connection typically pressure modules with a pressure range higher than 20 bar , apply the counterforce with a spanner on the connector bodys hexagonal part. The overpressure protection of the internal pressure modules vents to the back of the calibrator. Remember to be cautious when working with pressure and pressure modules.

See also chapters Safety on page 25 and Safety Precautions and Warnings on page The Front Panel The front panel has several sections. Some of them are pointed out with a callout in the picture of Operational Sections and Connections, and some of them not e. The ones with a callout are discussed first in the following paragraphs.

Electrical Module E module The E module can measure the following quantities: voltage, current and frequency.

It can also be used when counting pulses or detecting the state of a switch. Additionally there is a possibility to sink current. This allows communication with an instrument with HART capabilities. To ensure proper HART communication, make sure that the loop also includes a resistor with a resistance between to ohm or that the impedance of the loop itself is at least ohms.

It is not however restricted to only temperature instrument use because it can also generate voltage, frequency and pulses. Additionally the ET module is able to sink current. Resistance and RTD measurement. Resistance and RTD simulation. Voltage, frequency and pulse generation. Current sink.

JOHN FROW WHAT WAS POSTMODERNISM PDF

BEAMEX MC5-IS User Manual

Quick Links. Download this manual. Table of Contents. We have made every effort to ensure the accuracy of the contents of this manual. Should any errors be detected, we would greatly appreciate to receive suggestions. The above not withstanding, we can assume no responsibility for any errors in this.

ASTM A265 PDF

Beamex MC5

Beamex MC5 is no longer in production. Recommended replacement is Beamex MC6. Accuracy meets versatility. Beamex MC5 is the all-in-one documenting multifunction calibrator for calibrating pressure, temperature, electrical and frequency signals.

Related Articles